Nanjing JuQing
Focusing on various automation instruments
Accuracy | ±4% |
Output | Optional |
Flow switch | 2 |
LCD Display | - |
Communication | - |
Supply voltage | 12...32 VDC |
Protection level | IP 65 |
Process Connection | |
Catenate | 1/4" NPT、1/2" NPT、G1/4、Ferrule |
Flange | DN15、25/ 1/2"、1" |
- | - |
- | - |
Pressure level | |
HG/T 20592 | PN40、PN100* |
ASME B16.5 | 150、300、600 |
Measuring range | |
Liquid | 1.5...160l/h |
Gas | 16…4800 l/h |
Temperature range | |
Process temperature | -80…+150°C |
Ambient temperature(Non explosion-proof) | -40…+70°C |
Ambient temperature(Explosion-proof) | -40…+60°C |
Material quality | |
Shell | Cast aluminum (polyurethane coating) |
Liquid receiving components | Stainless steel, titanium, Hastelloy |
Authentication | |
Explosion proof certification | Ex ia ⅡC T6 Gb |